Product Overview
Harvard 900097 Lube Housing- 500 - Powder Coated
Used For
- Engine Oil
Recommended Elements
Capacity & Flow Rate
- Requires 12 Qt./11.4 L. of makeup fluid (housing volume)
- *Ideal sump range from 5-11 Gal./18.9-41.6 L.
- **Flow rate range from 0-1.25 GPM/0-4.7LPM
Overall Dimensions & Weight
- 14.25” (H) Plus 13” clearance above to change filter
- 10.62” (W)
- 10.75” (D)
- 25 LB. shipping weight
Other Specifications
- Max operating pressure, 80 PSI
- 1/2” FNPT inlet, outlet & drain ports
- ***Powder-coating inside and outside of housing
- Use with petroleum or synthetic fluids
Notes
- **Flow rates are established using ISO 10-1000 viscosity oils at the standard 40° C/104° F and are subject to vary
- *Viscosity, operating temperature, and generated contamination will affect sizing and flow rates of filtration equipment
- Most applications, elements need to be changed between 500-1000 hours for optimal performance, ideally change the element when the flow is half the starting flow or the PSI is double the starting PSI
- Available option for water-based lubricants